ColourSpace Integrated Hardware Operation
User guides for ColourSpace operation with our manufacturing partners.
User Guides
Any Display Calibration
Calibration of any TV & Projector via ColourSpace
Any Display Calibration
manual TV calibration more accurate than Autocal, 2-Point 10-Point 20-Point white balance controls, TV remote RGB balance adjustment live measurement, tv, television, hdr, sdr, dolby vision, lg, sony, panasonic, samsung, vizio, sharp, tcl, jvc, huawei, hitachi, hisense, toshiba, epson, philips
AccuPel
AccuPel TPG operation
AccuPel TPG
AccuPel DVG-5000 DGA-6000 discontinued models, USB serial connection 9600 baud 8-N-1, HDMI in and out passthrough, Video vs Data signal range option, AccuPel HDR options
Admesy Colourimeters
Admesy Colourimeters Operation
Admesy Colourimeters
Hyperion PCM2 Prometheus series probes, Integration Time and Gain manual settings, Auto Range Frequency Adjmin Max Int Time, Intelligent Integration low-light measurement, incorrect settings cause clipping and gamut compression
Admesy Spectrometers
Admesy Spectrometers Operation
Admesy Spectrometers
Hera Prometheus series spectrometers, Resolution and Interpolation spectrum settings, Integration Time Auto Range Frequency Adjmin, Intelligent Integration low-light, incorrect Admesy settings cause invalid readings
ColorBox
AJA ColorBox operation
AJA ColourBox
16x 1D and 16x 3D LUT non-volatile memory slots, Load Type 1D 3D 1D+3D upload options, Mode AJA Color pipeline setting, Unity Bypass overwrites only selected Load ID not global reset, LUT order issues front vs after signal path
ASUS
ASUS Calibration
ASUS Monitors
ASUS ProArt PA27UCX PA32UCX PA32DC model list, iTPG not bit-accurate must use RGB not YCbCr, internal ASUS probe selection, Dynamic Dimming backlight Extra Delay for HDR, 1D pre 3D 1D post LUT upload combinations
ASUS CaliContrO MCA02
MCA02 Probe Operation
ASUS CaliContrO MCA02
low cost tristimulus probe contact and non-contact modes, no specific calibration settings needed, Profile matrix preset drop-down, Average Low Light generic probe option
basICColor DISCUS
DISCUS Probe Operation
basICColor DISCUS
0.05 to 2500 cd/m2 range, glass filters thin-film optics long term stability, Normal Precision High Averaging Long Integration presets, built-in laser pointer Enable Visible Feedback, dark current Probe Calibration for low-light
BenQ
BenQ Calibration
BenQ Monitors
BenQ SW270C SW321C SW271C PV270 PD2770U model list, external TPG required for profiling not internal, Calibration-1 Calibration-2 OSD slots, ColourSpace Tetratune PRO/LTE manufacturer specific license
Boland
Boland Calibration
Boland Monitors
Monitor ID Space slot matching OSD, serial or network IP connection, 1D1 front 3D 1D2 back LUT slots, ColourSpace Boland PRO/LTE manufacturer specific license, shaper LUT front vs back workflow
Brompton Tessera
Brompton Integration
Brompton Tessera
LED Video Wall Processor IP Control network connection, Virtual Set screen profiling, Image Sequence Probe for camera lens screen path calibration, ColourSpace Brompton PRO/LTE license, Unity Bypass and Default Unity LUT
Calibrite/Display/i1D3
Display/i1D3 Probe Operation
Calibrite/Display/i1D3
Frequency Period AIO Sync Mode selection, correlation files SPD2Matrix accuracy limitation, avoid higher brightness models and Calman C6 versions, WOLED correlation file example, Intelligent Integration 6 second max, C6 HDR C6 HDR2000 HDR5000 variants, ambient light diffuser not for accurate measurement
Canon
Canon Calibration
Canon Monitors
Canon professional reference monitor network IP connection, Custom patch size via Canon Options, Unity Bypass resets all Load options not just selected LUT, external TPG for HDR HLG Dolby Vision metadata
CR-100/CR-200
CR-100/CR-200 Probe Operation
CR-100/CR-200
Colorimetry Research solid-state no moving parts, 0.0007 to 5150 cd/m2 luminance range, CRI Android App for matrix generation, Range Mode Max Auto Exposure Exposure Multiplier settings, Manual Sync Frequency PWM vs input signal, up to 20 stored display matrices
CR-250RH/CR-250
CR-250RH/CR-250 Probe Operation
CR-250RH/CR-250
Colorimetry Research 4nm bandwidth spectrometer, 0.02 to 154000 cd/m2 range, CMF Colour Matching Functions CIE Judd-Voss metameric correction, Exposure Mode Auto Manual Speed Slow Normal Fast 2xFast, probe matching unnecessary for spectrometer
CR-300RH/CR-300
CR-300RH/CR-300 Probe Operation
CR-300RH/CR-300
Colorimetry Research 2nm ultra-high resolution R&D reference spectrometer, laser projection narrow bandwidth applications, 0.02 to 154000 cd/m2, CMF Colour Matching Functions, Exposure Mode Speed settings, probe matching unnecessary for spectrometer
Craltech
Craltech Calibration
Craltech Monitors
Craltech PLUMA monitors, soft IP soft port OSD network settings, Gamut option selects DIT slot, Custom patch size via Craltech Options, ColourSpace Craltech PRO/LTE manufacturer specific license
Spyder Probes
DataColor Spyder Probes Operation
DataColor Spyder
not recommended for colour critical calibration poor accuracy, Spyder 4 5 onward models supported, Calibration matrix preset drop-down, Integration Time only on Spyder 4 and 5
Dell
Dell Calibration
Dell Monitors
Dell UP2720Q UP3221Q locked grey axis 3D LUT, unique two-pass native colour space then 1D+Matrix workflow, internal TPG wrong signal path position cannot be used, CAL1 CAL2 slots only, avoid Dell DUCCS software
Dolby
Dolby Calibration
Dolby Monitors
Dolby PRM network connection tricky use switch not direct cable, manual IP 192.168.1.101 subnet setup, slow patch generator needs 3-4 second Extra Delay, Locked Permissions preventing LUT upload
DVDO AVLab
DVDO AVLab TPG
DVDO AVLab TPG
discontinued TPG still integrated, RGB 0-255 vs YUV signal form options, YUV modes require Patch Scale Legal, USB serial connection, RGB Limited OSD not used by ColourSpace
EIZO
EIZO Calibration
EIZO Monitors
avoid ColorNavigator software compromises accuracy, Standard vs Extended LUT location before or after YUV to RGB, CG247X Extended LUT only RGB inputs, Emulated TPG Processor before LUT for verification, EIZO CG series backlight types LED phosphor
FSI BoxIO
FSI BoxIO LUT Box
FSI BoxIO LUT Box
Mode 1 single 333 LUT vs Mode 2 dual 173 LUT pipelines, Mode 3 Test Patch Generator, default IP 192.168.1.244 connection workaround via ad-hoc wifi, 1D-3D-1D image pipeline 16 saved LUTs each, SDI mini-DisplayPort passive HDMI DVI connector
hsg labs Spectro
hsg labs Spectro Operation
hsg labs Spectro
portable spectrometer 2nm bandwidth optional 1nm, integrated touch screen laser pointer, 0.01 to 9000 cd/m2 range, Screen Off During Measurement ambient light control, Spectrum Smoothing box filter, probe matching unnecessary for spectrometer
FSI
FSI Calibration
FSI Monitors
FSI XM XMP series direct integration, CFE CFE2 CFE3 monitors need manual LUT export via update cable, cannot self-verify GaiaColor calibration use ColourSpace DPS instead, Normal vs Advanced LUT Mode, DHCP IP address boot sequence, WOLED burn-in warning for windowed patterns
Jeti specbos 1211
Jeti specbos 1211 Probe Operation
Jeti specbos 1211
4.5nm spectral bandwidth, 0.2 to 100000 cd/m2 range, laser pointer alignment, Sync Frequency adoption error manual frame rate fix, probe matching unnecessary for spectrometer
Jeti spectraval 1501
Jeti spectraval 1501 Probe Operation
Jeti spectraval 1501
compact spectrometer 4.5nm bandwidth 2nm HiRes version, 0.2 to 140000 cd/m2 range, laser pointer alignment, Sync Frequency adoption error, probe matching unnecessary for spectrometer
Jeti spectraval 1511
Jeti spectraval 1511 Probe Operation
Jeti spectraval 1511
compact spectrometer 4.5nm bandwidth 2nm HiRes version, 0.2 to 140000 cd/m2 range, laser pointer alignment, Sync Frequency adoption error manual frame rate, probe matching unnecessary for spectrometer
Jeti specbos 2511
Jeti specbos 2511 Probe Operation
Jeti specbos 2511
built-in 4.3 inch touch display for direct measurement, battery and USB and Bluetooth interface, piezo-electric shutter dark signal compensation, 350-780nm range, NIST traceable calibration
Jeti specbos 2501
Jeti specbos 2501 Probe Operation
Jeti specbos 2501
4nm bandwidth 2nm HiRes version, 0.2 to 100000 cd/m2 range, NIR UV optional wavelength ranges, mechanical shutter dark signal compensation, USB 3.0 Bluetooth LAN interface, NIST traceable calibration
Klein K10-A
Klein K10-A Probe Operation
Klein K10-A
0.00006 to 10000 cd/m2 extreme low light sensitivity, laser aiming light fixed 12ft focus, 8 measurements per second, up to 90 stored display matrices, Klein Chromasurf matrix generation app, Max Integration Time default 4 seconds
Klein K-80
Klein K-80 Probe Operation
Klein K-80
small screen optics for phones tablets TVs, flicker measurement capability, 0.00009 to 10000 cd/m2, 8 measurements per second, up to 90 stored matrices, Klein Chromasurf app
Konvision
Konvision Calibration
Konvision Monitors
default IP 192.168.1.155 subnet 255.255.255.0 gateway 192.168.1.1, Custom patch size via Konvision Options, USB or network connection, ColourSpace Konvision PRO/LTE manufacturer specific license
LG Monitors
LG Monitors Calibration
LG Monitors
LG UltraFine 32EP950 27EP950 32BP95E 27BP95E models, USB-2 square connector not other USB, Calibration Picture Mode only for HDR PQ HLG, preset HDR modes use Gamma 2.2 not direct PQ, Picture Mode locked after calibration needs GUI reset, OLED burn-in warning at high luminance
LG TVs
LG TV Calibration
LG TVs
WOLED TVs 2017-2026 B/C/G/W model years, double-digit EU models C41 C42 G42 lack LUT calibration, Technicolor Studio Firmware requirement, PIN pairing TV expects mobile connection, HDR Tone Mapping Peak Luma nits, Dolby Vision EOTF config file upload, 1D LUT after 3D LUT signal order, Extract Space targeting native colour space for HDR, TV Legal vs Extended Range Contrast 100 vs 85 setting
LightSpace Connect
Android and iOS Test Patch Generation
LightSpace Connect
developed by caplaz.com not Light Illusion, free version 25 patch limit, HDR video clips via Video Generator plus DIP Mode playback, Chromecast TV Legal rescaling clipping test 0,0,0 vs 16,16,16, Screen Mirroring AirPlay MHL Cable connection
Lumagen Radiance
Lumagen Radiance Video Processors
Lumagen LUT Boxes
Factory Reset via remote Menu/0999 for connection issues, Termination character Echo response RS232 reporting OFF, BrightnessCal gamma test image for HDMI configuration check, 1D must upload before 3D due to signal order, Disable input reset on NULL upload option
madVR
madVR HTPC & Envy
madVR HTPC & Envy
madTPG.exe LAN Access Enabled network setting, Patch Scale must be Full due to madVR signal path, Envy 1D1 front 3D 1D2 back LUT slots, Temp slot not saved through power cycle, HTPC LUT needs Video Scale rescaling limitation, native 256 cubed LUT vs Calman locked to 33 cubed
Megapixel HELIOS
Megapixel Integration
Megapixel HELIOS
3D LUT capability requires HELIOS Alpha firmware, Input 3D LUT vs Post 3D LUT workflow, Virtual Set screen profiling, Image Sequence Probe for camera lens screen path, ColourSpace Megapixel PRO/LTE license
Minolta
Minolta Probes Operation
Minolta Probes
CA-210 CA-310 CA-410 CA-527 range colourimeters and spectros, interchangeable probe heads, Max Integration Time Maximum Exposure Time settings, Matrix Presets, Sync Frequency Auto or Manual
Mistika
Mistika TPG & LUTs
Mistika Grading System
SGO Mistika mConfig 3D LUT tab Network setup, Start Socket Colour Connection, dedicated video output card, Calibration Patches set to Automatic, Patch Size Position may not work check SGO integration status
Murideo SEVEN-G
Murideo SEVEN-G Operation
Murideo SEVEN-G
8 DRM preset HDR metadata slots MD Peak MaxCLL MaxFALL, Dolby Vision VSIF DoVi LL mode configuration, TPG Mode DoVi vs Off for low latency, 0-255 Full Range preferred over 16-235, 8K 4K UHD HDR HLG test patterns, professional displays need no HDR metadata
Murideo SIX-G
Murideo SIX-G Operation
Murideo SIX-G
SIX-G only accepts 8-bit input regardless of Settings Resolution, EDID Read Save emulate any display, HDCP 2.2 18Gbps AV integration testing, 8 DRM preset HDR metadata slots, Dolby Vision VSIF DoVi LL mode, 0-255 Full Range preferred over 16-235 SMPTE
MYIRO-1
MYIRO-1 Probe Operation
MYIRO-1
Minolta MYIRO-1 spectrophotometer, USB or WiFi connection type Select, multiple unit selection, probe matching unnecessary for spectrometer, contact and non-contact projection and monitor use
Other Probes
Other ColourSpace Integrated Probes
Other Probes
EIZO ASUS LG Dell internal probes support, any Spectro can be used for Probe Matching regardless of integration, use manufacturer software to pre-select matrix if not in ColourSpace, generic probe settings for undocumented probes
PatternSpace
MacOS Test Patch Generator
PatternSpace
developed by caplaz.com, Metal EDR pipeline 16-bit rgba16Float rendering, Pro Display XDR HDR headroom, ColorSync ICC toggle raw device code values, UDP auto-discovery Network Server connection, Strict App Sandbox no outgoing network traffic
Patterns
Mac Pattern Generator
Patterns
superseded by PatternSpace operation not guaranteed on modern MacOS, cannot be used as stand-alone TPG due to Apple ColorSync always active OS-wide, requires same Mac as display input source
Photo Research
Photo Research Probe Operation
Photo Research
PR-655 PR-670 PR-680 Cinebrate range, benchtop and portable colourimeters and spectros, Max Integration Time Matrix Presets settings, Intelligent Integration low-light
Plura
Plura Calibration
Plura Monitors
Monitor ID Space slot matching OSD, serial or network IP connection, Unity Bypass resets selected slot, Peak Luma Interactive Controls white point setup, external TPG option for HDR metadata
PGenerator
PGenerator Operation
PGenerator
Raspberry Pi 4 only not Pi5, balenaEtcher SD card flashing setup, PuTTY login pgenerator/pgenerator for updates, WiFi not recommended causes TPG issues, Bluetooth IP 10.10.11.1 USB IP 10.10.12.1, Ted's ISO advanced test patterns purchase, ColourSpace ZRO compatible free version
Qalif Spectro
Qalif Spectro Operation
Qalif Spectro
portable spectrometer 2nm bandwidth optional 1nm, integrated touch screen laser pointer, 0.01 to 9000 cd/m2, Fix or Automatic Integration Time dropdown, probe matching unnecessary for spectrometer
Resolve
Resolve TPG & LUTs
Resolve Grading System
Resolve limited to 8-bit TPG output regardless of ColourSpace setting, BG Colour bug must stay zero black, Aulwa Addon for 10-bit workflow, Workspace Monitor Light Illusion menu connection, Full Range Resolve with ColourSpace Patch Scale, 10-bit rounding errors known bug
Scratch
Scratch TPG & LUTs
Scratch Grading System
calPatch.spa calPatch.tif plugin files for pre-v9.3, built-in from Scratch v9.3 onward, ASSIMILATE_PLUGINS environment variable, CustomCommands.xml button setup, Tools menu custom command jumps to Player Calibration menu
TCL
TCL TV Calibration
TCL TVs
no internal TPG LUT upload via FAT32 USB stick only, PIDxxxx naming convention 1tcl 3tcl file extensions, Project ID 4 digit code from About menu, Filmmaker Movie Game Dolby Vision modes, PQ HDR uses only 1D LUT no 3D LUT support, DV Config Tmin Tmax Tgamma ColorPrimaries parameters
Topcon
Topcon SR Spectro Operation
Topcon
SR series spectrometer from 0.0001 nits, Serial connection not USB CS-900A protocol, Measurement Mode AUTO FREQ MANUAL SYNC, Yxy Only vs Yxy Spectral metric, probe matching unnecessary for spectrometer
TVLogic
TVLogic Calibration
TVLogic Monitors
tvlogic monitor, broadcast monitor calibration, television, hdr, display, colour critical monitor
TVLogic IS-mini
TVLogic IS-mini LUT Box
TVLogic IS-mini
IS-mini IS-miniX IS-mini4K models 26 cubed LUT, USB connection SDI HDMI, TV Legal clipping test Black 000 vs Grey 013 8-bit, Video Scale pre-processing for Legal Range upload
UPRtek
UPRtek Probe Operation
UPRtek
MD100N MK550T handheld and tripod models, 9nm bandwidth 0.001 to 5000 cd/m2, Exposure Mode Auto Manual uSec setting, Sync Mode On Off frequency, probe matching unnecessary for spectrometer
Videoforge
Videoforge Operation
Videoforge
Calman rebranded Murideo Fox and Hound cut-down SIX-G firmware, limited not a real SIX-G alternative but useful for Calman users trading up, v1.13 firmware, operation same as SIX-G guide
Videworks Tetratune
Tetratune Video Processor
Videworks Tetratune
100 selectable 33 cubed LUTs WebUI control, tetrahedral interpolation HDCP 1.4 2.2 2.3 support, unique Input Screen Mode name combination for LUT slot naming, Demo Mode split-screen LUT vs bypass, TPG Settings General Colour HDR override
X-Rite i1Pro
i1Pro 1/2/3 & Plus Probe Operation
X-Rite i1Pro
i1Pro 1 2 3 spectrometer, EFI ES-2000 ES-3000 rebranded versions, in-built timer needs recalibration due to heat drift, should only be used for probe matching not actual profiling, calibration plate serial number must match probe